Ultrasonographic and hemodynamic characteristics of patients with symptomatic carotid near-occlusion: results from a multicenter registry study

Fecha de publicación: Fecha Ahead of Print:

Autores de I3PT

Participantes ajenos a I3PT

  • Palacios-Mendoza, MA
  • Pastor, AG
  • Gil-Nunez, A
  • Ramirez-Moreno, JM
  • Gonzalez-Nafria, N
  • Moniche, F
  • Portilla-Cuenca, JC
  • Fuentes, B
  • Gamero-Garcia, MA
  • de Lecinana, MA
  • Masjuan, J
  • Aladro, Y
  • Lago, A
  • de Arce-Borda, AM
  • Usero-Ruiz, M
  • Delgado-Mederos, R
  • Pampliega, A
  • Ximenez-Carrillo, A
  • Bartulos-Iglesias, M
  • Castro-Reyes, E
  • Spanish Cerebrovasc Dis Study Grp

Grupos de Investigación

Abstract

Purpose The ultrasonographic and hemodynamic features of patients with carotid near-occlusion (CNO) are still not well known. Our aim was to describe the ultrasonographic and hemodynamic characteristics of a cohort of patients with CNO. Methods A prospective, observational, nationwide, and multicenter study was conducted from January/2010 to May/2016. Patients with digital subtraction angiography (DSA)-confirmed CNO were included. We collected information on clinical and demographic characteristics, carotid and transcranial ultrasonography and DSA findings, presence of full-collapse, collateral circulation, and cerebrovascular reactivity (CVR). Results One hundred thirty-five patients were analyzed. Ultrasonographic and DSA diagnosis of CNO were concordant in only 44%. This disagreement was related to the presence/absence of full-collapse: 45% of patients with CNO with full-collapse were classified as a complete carotid occlusion, and 40% with a CNO without full-collapse were interpreted as severe stenosis (p< 0.001). Mean velocities (mV) and pulsatility indexes (PIs) were significantly lower in the ipsilateral middle cerebral artery compared with the contralateral (43 cm/s vs 58 cm/s,p< 0.001; 0.80 vs 1.00,p< 0.001). Collateral circulation was identified in 92% of patients, with the anterior communicating artery (73%) being the most frequent. CVR was decreased or exhausted in 66% of cases and was more frequent in patients with a poor or absent collateral network compared with patients with >= 2 collateral arteries (82% vs 56%,p= 0.051). Conclusion The accuracy of carotid ultrasonography in the diagnosis of CNO seems to be limited, with significant discrepancies with DSA. Decreased ipsilateral mV, PI, and CVR suggest a hemodynamic compromise in patients with CNO.

Datos de la publicación

ISSN/ISSNe:
0028-3940, 1432-1920

NEURORADIOLOGY  SPRINGER

Tipo:
Article
Páginas:
705-711
PubMed:
33025041

Citas Recibidas en Web of Science: 17

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Carotid near-occlusion; Carotid stenosis; Ultrasonography; Hemodynamics; Collateral circulation; Cerebrovascular reactivity

Campos de Estudio

Cita

Compartir