Metal Ion Release in Cancer Patients Following Megaprosthesis Salvage Surgery

Fecha de publicación: Fecha Ahead of Print:

Autores de I3PT

Participantes ajenos a I3PT

  • Fa-Binefa, M
  • Peiró, A
  • Trullols, L
  • Machado, P
  • Gracia, I

Grupos de Investigación

Abstract

Background: Megaprostheses contain many more modular components than conventional total hip and knee arthroplasty, which may lead to higher serum levels of metal ions. The aim of this study was to determine serum concentrations of titanium, chromium, and cobalt ions in cancer patients after limb salvage surgery with a megaprosthesis. Methods: A retrospective, descriptive cohort analysis consisting of patients who underwent cancer- related limb salvage surgery with a megaprosthesis at our hospital between 2010 and 2020 was conducted. Baseline and follow-up data were extracted from clinical and surgical records. Blood samples were prospectively obtained. Descriptive statistics were used for the analysis. Results: A total of 71 patients underwent limb salvage surgery during the study period. Of these, 22 (10 women, 12 men) were included in the study. The mean age was 52 years (range, 21 to 80). Most cases (n = 16; 72.7%) involved the femur. Most patients (n = 14, 63.6%) underwent total knee megaprosthesis surgery. Implant revision surgery was required in 45% of cases (n = 10), with a mean interval of 4.32 years between the initial and revision surgeries. The mean follow-up time after revision surgery was 4.05 years. High levels of chromium were observed in 22.7% of patients (n = 5). High cobalt levels were found in 68.2% (n = 15) of patients, with toxic levels in 9.1% (n = 2). Titanium levels were high in 77.3% (n = 17) of cases and toxic in 22.7% (n = 5). Postoperative chemotherapy was significantly associated with titanium levels (P = .017). No correlation was observed between metal ion levels and time from primary or revision surgery or time from the first to revision surgery. Conclusions: This study shows that cancer-related limb salvage surgery with megaprosthesis is associated with metal ion levels that exceed established safe thresholds. Compared to conventional hip arthroplasty, a higher proportion of the patients in this cohort presented elevated levels of metal ions. Level of evidence: III. (c) 2024 Elsevier Inc. All rights reserved.

Datos de la publicación

ISSN/ISSNe:
0883-5403, 1532-8406

JOURNAL OF ARTHROPLASTY  CHURCHILL LIVINGSTONE INC MEDICAL PUBLISHERS

Tipo:
Article
Páginas:
2336-2340
PubMed:
38640965
Enlace a otro recurso:
www.scopus.com

Citas Recibidas en Web of Science: 5

Citas Recibidas en Scopus: 1

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • metal ion levels; megaprosthesis salvage surgery; megaprosthesis; orthopaedic oncology; modular components; titanium-chromium-cobalt