Specific Training Improves the Detection and Management of Patient-Ventilator Asynchrony
Fecha de publicación:
Autores de I3PT
Participantes ajenos a I3PT
- Ramírez, II
- Gutiérrez-Arias, R
- Damiani, LF
- Adasme, RS
- Arellano, DH
- Salinas, FA
- Roncalli, A
- Núñez-Silveira, J
- Santillán-Zuta, M
- Sepúlveda-Barisich, P
- Gordo-Vidal, F
Grupos de Investigación
Abstract
BACKGROUND: Patient -ventilator asynchrony is common in patients undergoing mechanical ventilation. The proportion of health-care professionals capable of identifying and effectively managing different types of patient -ventilator asynchronies is limited. A few studies have developed specific training programs, but they mainly focused on improving patient -ventilator asynchrony detection without assessing the ability of health-care professionals to determine the possible causes. METHODS: We conducted a 36-h training program focused on patient -ventilator asynchrony detection and management for health-care professionals from 20 hospitals in Latin America and Spain. The training program included 6 h of a live online lesson during which 120 patient -ventilator asynchrony cases were presented. After the 6-h training lesson, health-care professionals were required to complete a 1-h training session per day for the subsequent 30 d. A 30 -question assessment tool was developed and used to assess health-care professionals before training, immediately after the 6-h training lecture, and after the 30 d of training (1 -month follow-up).RESULTS: One hundred sixteen health-care professionals participated in the study. The median (interquartile range) of the total number of correct answers in the pre -training, post -training, and 1 -month follow-up were significantly different (12 [8.75-15], 18 [13.75-22], and 18.5 [14-23], respectively). The percentages of correct answers also differed significantly between the time assessments. Study participants significantly improved their performance between pre -training and post -training (P < .001). This performance was maintained after a 1 -month follow-up (P 5 .95) for the questions related to the detection, determination of cause, and management of patient -ventilator asynchrony. CONCLUSIONS: A specific 36-h training program significantly improved the ability of health-care professionals to detect patient -ventilator asynchrony, determine the possible causes of patient -ventilator asynchrony, and properly manage different types of patient -ventilator asynchrony.
Datos de la publicación
- ISSN/ISSNe:
- 0020-1324, 1943-3654
- Tipo:
- Article
- Páginas:
- 166-175
- PubMed:
- 38267230
- Enlace a otro recurso:
- www.scopus.com
Respiratory Care SAGE PUBLICATIONS INC
Citas Recibidas en Web of Science: 11
Citas Recibidas en Scopus: 3
Documentos
- No hay documentos
Filiaciones
Keywords
- mechanical ventilation; intensive care unit; patient-ventilator interaction; patient-ventilator asynchrony; critically ill patient; critical care
Campos de Estudio
Cita
Ramírez II,Gutiérrez R,Damiani LF,Adasme RS,Arellano DH,Salinas FA,Roncalli A,Núñez J,Santillán M,Sepúlveda P et al. Specific Training Improves the Detection and Management of Patient-Ventilator Asynchrony. Respir. Care. 2024. 69. (2):p. 166-175. DOI: 10.4187/respcare.11329.
Portal de investigación