Multivariable Regression Model to Estimate Tidal Volume for Different Respiratory Patterns

Fecha de publicación:

Autores de I3PT

Participantes ajenos a I3PT

  • Pérez D.R.
  • Solà Soler J.
  • Balchin L.
  • Serra A.M.
  • Popoviciu Koborzan M.R.
  • Giraldo B.F.

Grupos de Investigación

Abstract

Respiratory patterns present great variability, both in healthy subjects and in patients with different diseases and forms of nasal, oral, superficial or deep breathing. The analysis of this variability depends, among others, on the device used to record the signals that describe these patterns. In this study, we propose multivariable regression models to estimate tidal volume (VT) considering different breathing patterns. Twenty-three healthy volunteers underwent continuous multisensor recordings considering different modes of breathing. Respiratory flow and volume signals were recorded with a pneumotachograph and thoracic and abdominal respiratory inductive plethysmographic bands. Several respiratory parameters were extracted from the volume signals, such as inspiratory and expiratory areas (Areains, Areaexp), maximum volume relative to the cycle start and end (VTins, VTexp), inspiratory and expiratory time (Tins, Texp), cycle duration (Ttot), and normalized parameters of clinical interest. The parameters with the greatest individual predictive power were combined using multivariable models to estimate VT. Their performance were quantified in terms of determination coefficient (R2), relative error (ER) and interquartile range (IQR). Using only three parameters, the results obtained for the thoracic band (VTexp, Ttot, Areaexp) were better than those obtained from the abdominal band (VTexp, Tins, Areains) with R2 = 0.94 (IQR: 0.07); ER = 6.99 (IQR: 6.12) vs R2 = 0.91 (IQR: 0.09), ER = 8.70 (IQR: 4.62). Overall performance increased to R2 = 0.97 (IQR: 0.02) and ER = 4.60 (IQR: 3.68) when parameters from the different bands were combined, further improving when was applied to segments with different inspiration-expiration patterns. In particular, the nose-nose ER = 1.39 (IQR: 0.73), nose-mouth ER = 2.11 (IQR: 1.23) and mouth-mouth ER = 2.29 (IQR: 1.44) patterns showed the best results compared to those obtained for basal, shallow and deep breathing.Clinical relevance - Respiratory pattern variability can be described using multivariable regression model for tidal volume. © 2023 IEEE.

Datos de la publicación

ISSN/ISSNe:
1557-170X, 1558-4615

2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC)  Institute of Electrical and Electronics Engineers Inc.

Tipo:
Conference Paper
Páginas:
-
PubMed:
38082854
Enlace a otro recurso:
www.scopus.com

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Humans; Nose; Respiration; Respiratory Rate; Tidal Volume; Regression analysis; Respiratory mechanics; Breathing patterns; Healthy subjects; Healthy volunteers; Inter quartile ranges; Multisensor recordings; Multivariable regression model; Performance; Respiratory flow; Respiratory pattern; Tidal volume; breathing; breathing rate; human; nose; tidal volume; Tin

Cita

Compartir