Mammographic breast density: How it affects performance indicators in screening programmes?
Autores de I3PT
Participantes ajenos a I3PT
- Posso, M
- Louro, J
- Sanchez, M
- Roman, M
- Vidal, C
- Sala, M
- Castells, X
- Buron, A
- Domingo, L
- Rodriguez-Arana, A
- Servitja, S
- Vernet, M
- Benito, L
- Quintana, MJ
- Sola-Roca, J
- Prieto, M
- Galceran, J
- Saladie, F
- Ferrer, J
- Espinas, JA
- Penalva, L
- Tora-Rocamora, I
- Bargallo, X
- BELE Study Grp
Abstract
Objectives: To investigate how breast density affects screening performance indicators in a digital mammography context. Methods: We assessed the effect of breast density over the screen-detected and interval cancers rates, false-positives, specificity, sensitivity, recall rate, positive predictive value of recall (PPV-1), and PPV of invasive tests (PPV-2). Radiologists classified breast density using the BIRADS System. We used generalized estimating equations to account for within-woman correlation by means of the robust Huber-While variance estimator. Results: We included 177,164 women aged 50-69 years who underwent 499,251 digital mammograms from 2004 to 2015 in Spain. According to the fibroglandular tissue percentage, 24.7% of mammograms were classified as BI-RADS 1 ( < 25% glandular), 54.7% as BI-RADS 2 (25-50% glandular), 14.0% as BI-RADS 3 (51-75% glandular) and 6.6% as BI-RADS 4 ( > 75% glandular). Overall, women with BI-RADS 3 had the highest screen-detected cancer rate (5.9 per 1000) and BI-RADS 4 the highest interval cancer rate (2.4 per 1000). Sensitivity decreased from 89.2% in women with BI-RADS 1 to 67.9% in BI-RADS 4. Both PPV-1 and PPV-2 decreased from 10.4% to 5.7% and from 49.8% to 32.4% in women with BI-RADS 1 and BI-RADS 4, respectively. Women aged 60-69 years with BI-RADS 4 had the lowest sensitivity (54.9%) and the highest interval cancer rate (3.8 per 1000). Conclusions: Performance screening measures are negatively affected by breast density falling to a lower sensitivity and PPV, and higher interval cancer rate as breast density increases. Particularly women aged 60-69 years with > 75% glandular breasts had the worst results and therefore may be candidates for screening using other technologies.
Datos de la publicación
- ISSN/ISSNe:
- 0720-048X, 1872-7727
- Tipo:
- Article
- Páginas:
- 81-87
- PubMed:
- 30599878
EUROPEAN JOURNAL OF RADIOLOGY ELSEVIER IRELAND LTD
Citas Recibidas en Web of Science: 33
Documentos
- No hay documentos
Filiaciones
Keywords
- Breast neoplasms; Early detection of cancer; Mammography; Breast density
Campos de Estudio
Cita
Posso M,Louro J,Sanchez M,Roman M,Vidal C,Sala M,Bare M,Castells X,Buron A,Domingo L et al. Mammographic breast density: How it affects performance indicators in screening programmes?. Eur. J. Radiol. 2019. 110. p. 81-87. DOI: 10.1016/j.ejrad.2018.11.012.
Portal de investigación