Interobserver reliability of Masei index validation by a multicenter collaborative group of rheumatologists.

Fecha de publicación: Fecha Ahead of Print:

Autores de I3PT

Participantes ajenos a I3PT

  • Moya Alvarado P
  • de Agustín de Oro JJ
  • Aparicio Espinar M
  • Armengol Pérez E
  • Busquets Pérez N
  • Carmona L
  • Clavaguera Poch T
  • Cuervo Aguilera A
  • De Miguel Mendieta E
  • Estrada Alarcón P
  • García Casares E
  • Holgado Pérez S
  • Magallares López B
  • Martinez Morillo M
  • Mateo Soria L
  • Moragues Pastor C
  • Ponce Fernández A
  • Pujol Busquets M
  • Ramírez García J
  • Reina Sanz D
  • Sallés Lizarzaburu M
  • Santo Panero P
  • Sirvent Alierta E
  • Valls Roc M
  • Corominas Macías H

Grupos de Investigación

Abstract

MASEI is the main validated ultrasound score for the evaluation of enthesis. The lack of studies facing the agreement to achieve for the interpretation of the MAdrid Sonographic Enthesis Index (MASEI) among researchers from different centers in multicenter studies is of concern. The aim of this multicenter was to evaluate the interobserver reliability of MASEI. An experienced ultrasonographer-rheumatologist performed ultrasound scans of the areas included in MASEI index in three patients with Ankylosing Spondylitis and Psoriatic Arthritis. Videos were captured. The videos were then evaluated by 24 rheumatologists of the ultrasound working group of the Catalan Society of Rheumatology (EcoCAT). A face-to-face training meeting was held. Ten days after the workshop, the study participants evaluated the videos. A reliability assessment was performed. The ICC for the MASEI scores after the workshop was of 0.97 (95% CI 89-99). Reliability did not vary statistically with examiner experience. Globally, no problems of reliability by structures were seen, and all the ICCs were above 0.90 and improved slightly after the educational program. However, the correlation observed between examiners at plantar aponeursis and triceps tendon was weak. The small variability observed in the results of the index validation in our study, suggests that the MASEI index is reproducible by different observers when those are well trained and show awesome results of the enthesis when examined by ultrasound.

Datos de la publicación

ISSN/ISSNe:
0172-8172, 1437-160X

RHEUMATOLOGY INTERNATIONAL  SPRINGER HEIDELBERG

Tipo:
Article
Páginas:
441-448
PubMed:
33146762
Enlace a otro recurso:
www.scopus.com

Citas Recibidas en Web of Science: 6

Citas Recibidas en Scopus: 1

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Interobserver reliability, Masei, Spondyloarthropathy, Ultrasound

Campos de Estudio

Compartir