Dynamic use of fibrinogen under viscoelastic assessment results in reduced need for plasma and diminished overall transfusion requirements in severe trauma

Fecha de publicación:

Autores de I3PT

Participantes ajenos a I3PT

  • Lopez, MB
  • Valencia, AM
  • Velazquez, AG
  • Puyana, JC

Grupos de Investigación

Abstract

BACKGROUND: Despite advances in trauma management, half of trauma deaths occur secondary to bleeding. Currently, hemostatic resuscitation strategies consist of empirical transfusion of blood products in a predefined fixed ratio (1:1:1) to both treat hemorrhagic shock and correct trauma-induced coagulopathy. At our hospital, the implementation of a resuscitation protocol guided by viscoelastic hemostatic assays (VHAs) with rotational thromboelastometry has resulted in a goal-directed approach. The objective of the study is twofold, first to analyze changes in transfusion practices overtime and second to identify the impact of these changes on coagulation parameters and clinical outcomes. We hypothesized that progressive VHA implementation results in a higher administration of fibrinogen concentrate (FC) and lower use of blood products transfusion, especially plasma. METHODS: A total of 135 severe trauma patients (January 2008 to July 2019), all requiring and initial assessment for high risk of trauma-induced coagulopathy based on high-energy injury mechanism, severity of bleeding and hemodynamic instability were included. After 2011 when we first modified the transfusion protocol, a progressive change in transfusional management occurred over time. Three treatment groups were established, reflecting different stages in the evolution of our strategy: plasma (P, n = 28), plasma and FC (PF, n = 64) and only FC (F, n = 42). RESULTS: There were no significant differences in baseline characteristics among groups. Progressive implementation of rotational thromboelastometry resulted in increased use of FC over time (p < 0.001). Regression analysis showed that group F had a significant reduction in transfusion of packed red blood cells (p = 0.005), plasma (p < 0.001), and platelets (p = 0.011). Regarding outcomes, F patients had less pneumonia (p = 0.019) and multiorgan failure (p < 0.001), without significant differences for other outcomes. Likewise, overall mortality was not significantly different. However, further analysis comparing specific mortality due only to massive hemorrhage in the F group versus all patients receiving plasma, it was significantly lower (p = 0.037). CONCLUSION: Implementing a VHA-based algorithm resulted in a plasma-free strategy with higher use of FC and a significant reduction of packed red blood cells transfused. In addition, we observed an improvement in outcomes without an increase in thrombotic complications. Copyright (c) 2022 American Association for the Surgery of Trauma.

Datos de la publicación

ISSN/ISSNe:
2163-0755, 2163-0763

Journal of Trauma and Acute Care Surgery  LIPPINCOTT WILLIAMS & WILKINS

Tipo:
Article
Páginas:
166-175
PubMed:
35358159
Enlace a otro recurso:
www.scopus.com

Citas Recibidas en Web of Science: 12

Citas Recibidas en Scopus: 3

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Coagulopathy; viscoelastic assays; fibrinogen; massive transfusion; trauma

Campos de Estudio

Cita

Compartir